Chromatographie en phase liquide-spectrométrie de masseLa chromatographie en phase liquide couplée à la spectrométrie de masse (en anglais Liquid chromatography-mass spectrometry ou LC-MS) est une méthode d'analyse qui combine les performances de la chromatographie en phase liquide et de la spectrométrie de masse afin d'identifier et/ou de quantifier précisément de nombreuses substances. Une unité LC-MS est composée de deux blocs principaux : un chromatographe en phase liquide et un spectromètre de masse. Catégorie:Méthode de la biochimie Catégorie:Chromatogra
Quantum dot solar cellA quantum dot solar cell (QDSC) is a solar cell design that uses quantum dots as the captivating photovoltaic material. It attempts to replace bulk materials such as silicon, copper indium gallium selenide (CIGS) or cadmium telluride (CdTe). Quantum dots have bandgaps that are adjustable across a wide range of energy levels by changing their size. In bulk materials, the bandgap is fixed by the choice of material(s).
Cellule photovoltaïqueUne cellule photovoltaïque, ou cellule solaire, est un composant électronique qui, exposé à la lumière, produit de l’électricité grâce à l’effet photovoltaïque. La puissance électrique obtenue est proportionnelle à la puissance lumineuse incidente et elle dépend du rendement de la cellule. Celle-ci délivre une tension continue et un courant la traverse dès qu'elle est connectée à une charge électrique (en général un onduleur, parfois une simple batterie électrique).
Film photovoltaïqueUn film photovoltaïque ou cellule solaire en couche mince ou encore couche mince photovoltaïque est une technologie de cellules photovoltaïques de deuxième génération, consistant à l'incorporation d'une ou plusieurs couches minces (ou TF pour ) de matériau photovoltaïque sur un substrat, tel que du verre, du plastique ou du métal. Les couches minces photovoltaïques commercialisées actuellement utilisent plusieurs matières, notamment le tellurure de cadmium (de formule CdTe), le diséléniure de cuivre-indium-gallium (CIGS) et le silicium amorphe (a-Si, TF-Si).
Spectromètre de masse à temps de volLa spectrométrie à temps de vol (TOF-MS, selon l'acronyme anglais en) est une méthode de spectrométrie de masse dans laquelle les ions sont accélérés par un champ électrique de valeur connue. Il résulte de cette accélération que les ions de même charge électrique acquièrent la même quantité de mouvement. La vitesse des ions, par contre, dépend du rapport masse sur charge. On mesure le temps mis par une particule chargée pour atteindre un détecteur situé à une distance connue.
Chemical ionizationChemical ionization (CI) is a soft ionization technique used in mass spectrometry. This was first introduced by Burnaby Munson and Frank H. Field in 1966. This technique is a branch of gaseous ion-molecule chemistry. Reagent gas molecules (often methane or ammonia) are ionized by electron ionization to form reagent ions, which subsequently react with analyte molecules in the gas phase to create analyte ions for analysis by mass spectrometry.
Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.
Spectrométrie de masse des ions secondairesLa spectrométrie de masse des ions secondaires est un procédé d'analyse de surface connu sous le nom de SIMS, d'après l'acronyme anglais signifiant secondary ion mass spectrometry, qui consiste à bombarder la surface de l'échantillon à analyser avec un faisceau d'ions. L'échantillon est alors pulvérisé, et une partie de la matière pulvérisée est ionisée. Ces ions secondaires sont alors accélérés vers un spectromètre de masse qui permettra de mesurer la composition élémentaire, isotopique ou moléculaire de la surface de l'échantillon.
Capillary electrophoresis–mass spectrometryCapillary electrophoresis–mass spectrometry (CE–MS) is an analytical chemistry technique formed by the combination of the liquid separation process of capillary electrophoresis with mass spectrometry. CE–MS combines advantages of both CE and MS to provide high separation efficiency and molecular mass information in a single analysis. It has high resolving power and sensitivity, requires minimal volume (several nanoliters) and can analyze at high speed.
Chimie analytiqueLa chimie analytique est la partie de la chimie qui concerne l'analyse des produits, c'est-à-dire l'identification et la caractérisation de substances chimiques connues ou non. La substance chimique dont on cherche à déterminer les propriétés est appelée « analyte ». Ses applications vont du suivi de production (vérifier qu'une chaîne fabrique un produit conforme aux spécifications) à l'enquête policière (déterminer la nature d'une trace, la provenance d'une terre, d'une peinture).