Microelectrode arrayMicroelectrode arrays (MEAs) (also referred to as multielectrode arrays) are devices that contain multiple (tens to thousands) microelectrodes through which neural signals are obtained or delivered, essentially serving as neural interfaces that connect neurons to electronic circuitry. There are two general classes of MEAs: implantable MEAs, used in vivo, and non-implantable MEAs, used in vitro. Neurons and muscle cells create ion currents through their membranes when excited, causing a change in voltage between the inside and the outside of the cell.
Single-unit recordingIn neuroscience, single-unit recordings (also, single-neuron recordings) provide a method of measuring the electro-physiological responses of a single neuron using a microelectrode system. When a neuron generates an action potential, the signal propagates down the neuron as a current which flows in and out of the cell through excitable membrane regions in the soma and axon. A microelectrode is inserted into the brain, where it can record the rate of change in voltage with respect to time.
Culture cellulaireLa culture cellulaire est un ensemble de techniques de biologie utilisées pour faire croître des cellules hors de leur organisme (ex-vivo) ou de leur milieu d'origine, dans un but d'expérimentation scientifique ou de fécondation in vitro. Les cellules mises en culture peuvent être: des micro-organismes libres (bactéries ou levures) des cellules « saines » prélevées fraîchement d'un organisme (biopsie...), on parle alors de « culture primaire ».
Cultured neuronal networkA cultured neuronal network is a cell culture of neurons that is used as a model to study the central nervous system, especially the brain. Often, cultured neuronal networks are connected to an input/output device such as a multi-electrode array (MEA), thus allowing two-way communication between the researcher and the network. This model has proved to be an invaluable tool to scientists studying the underlying principles behind neuronal learning, memory, plasticity, connectivity, and information processing.
MagnétoencéphalographieLa magnétoencéphalographie (MEG) est une technique de mesure des champs magnétiques induits par l'activité électrique des neurones du cerveau. Cette technique est employée avec une visée clinique en neurologie (notamment pour l'étude de l'épilepsie) mais aussi en cardiologie, ainsi que dans la recherche en neurosciences cognitives. Les champs magnétiques mesurés étant extrêmement faibles (de l'ordre de quelques femtoteslas), la MEG utilise un appareillage basé sur des magnétomètres à SQUID placé dans une pièce isolée magnétiquement par du mu-métal.
Rythme cérébralUn rythme cérébral (appelé aussi activité neuro-électrique) désigne l'oscillation électromagnétique émise par le cerveau des êtres humains, mais également de tout être vivant. Le cortex frontal qui permet la cognition, la logique et le raisonnement est composé de neurones qui sont reliés entre eux par des synapses permettant la neurotransmission. Mesurables en volt et en hertz, ces ondes sont de très faible amplitude : de l'ordre du microvolt (chez l'être humain), elles ne suivent pas toujours une sinusoïde régulière.
Optical resolutionOptical resolution describes the ability of an imaging system to resolve detail, in the object that is being imaged. An imaging system may have many individual components, including one or more lenses, and/or recording and display components. Each of these contributes (given suitable design, and adequate alignment) to the optical resolution of the system; the environment in which the imaging is done often is a further important factor. Resolution depends on the distance between two distinguishable radiating points.
ÉlectrophysiologieL'électrophysiologie (du grec el, elektron, el, physis, nature, et -el, -logia, étude) est l'étude des phénomènes électriques et électrochimiques qui se produisent dans les cellules ou les tissus des organismes vivants et, en particulier, dans les neurones et les fibres musculaires et chez les plantes sensitives (étudiées depuis le début du siècle de ce point de vue, dont par Jagadish Chandra Bose). Elle implique la mesure de différences de tensions ou de courants électriques à différentes échelles biologiques, du canal ionique isolé, jusqu'à des organes entiers, comme le cœur.
Patch-sequencingPatch-sequencing (patch-seq) is a method designed for tackling specific problems involved in characterizing neurons. As neural tissues are one of the most transcriptomically diverse populations of cells, classifying neurons into cell types in order to understand the circuits they form is a major challenge for neuroscientists. Combining classical classification methods with single cell RNA-sequencing post-hoc has proved to be difficult and slow.
Patch-clampvignette|Enregistrement (picoAmpère en fonction du temps) d'un patch-clamp montrant les passages entre deux états de conductance d'un canal ionique : fermé (ligne du haut) et ouvert (ligne du bas). Patch-clamp est un terme anglais désignant une technique électrophysiologique d'enregistrement des courants ioniques transitant à travers les membranes cellulaires. Cette technique consiste à mettre en continuité électrique une micro-pipette en verre (diamètre de contact de l'ordre de 1 μm) remplie d'une solution ionique de composition définie avec la membrane d'une cellule vivante isolée.