Spectrométrie de massethumb|right|Spectromètre de masse La spectrométrie de masse est une technique physique d'analyse permettant de détecter et d'identifier des molécules d’intérêt par mesure de leur masse, et de caractériser leur structure chimique. Son principe réside dans la séparation en phase gazeuse de molécules chargées (ions) en fonction de leur rapport masse/charge (m/z). Elle est utilisée dans pratiquement tous les domaines scientifiques : physique, astrophysique, chimie en phase gazeuse, chimie organique, dosages, biologie, médecine, archéologie.
Tandem mass spectrometryTandem mass spectrometry, also known as MS/MS or MS2, is a technique in instrumental analysis where two or more mass analyzers are coupled together using an additional reaction step to increase their abilities to analyse chemical samples. A common use of tandem MS is the analysis of biomolecules, such as proteins and peptides. The molecules of a given sample are ionized and the first spectrometer (designated MS1) separates these ions by their mass-to-charge ratio (often given as m/z or m/Q).
Spectrométrie de masse à résonance cyclonique ioniqueLa spectrométrie de masse à résonance cyclotronique ionique (FT-ICR-MS) est un instrument possédant un haut pouvoir de résolution et une bonne exactitude sur la masse très important pour l’analyse des protéines. C’est une technique basée sur le piégeage et l’excitation des ions dans une cellule ICR (résonance cyclotronique des ions) sous l’action d’un champ électromagnétique. Le spectre de masse est obtenu via la transformée de Fourier qui convertit le signal temporel acquis en spectre de fréquence proportionnel à la masse.
Chromatographie en phase liquide-spectrométrie de masseLa chromatographie en phase liquide couplée à la spectrométrie de masse (en anglais Liquid chromatography-mass spectrometry ou LC-MS) est une méthode d'analyse qui combine les performances de la chromatographie en phase liquide et de la spectrométrie de masse afin d'identifier et/ou de quantifier précisément de nombreuses substances. Une unité LC-MS est composée de deux blocs principaux : un chromatographe en phase liquide et un spectromètre de masse. Catégorie:Méthode de la biochimie Catégorie:Chromatogra
Structure secondairethumb|200px|Schéma de la structure tridimensionnelle de la protéine myoglobine. Cette structure contient de hélices α mais pas de feuillets β. Cette protéine est la première dont la structure a été résolue par cristallographie en 1958, par Max Perutz et John Kendrew, ce qui leur a valu l'attribution du prix Nobel de chimie en 1962. En biochimie et en biologie structurale, la structure secondaire se rapporte uniquement à la description de la structure tridimensionnelle localement adoptée par certains segments de molécules biologiques (molécules définies comme étant des biopolymères, comme c’est le cas pour les protéines et les acides nucléiques (ADN/ARN)).
Capillary electrophoresis–mass spectrometryCapillary electrophoresis–mass spectrometry (CE–MS) is an analytical chemistry technique formed by the combination of the liquid separation process of capillary electrophoresis with mass spectrometry. CE–MS combines advantages of both CE and MS to provide high separation efficiency and molecular mass information in a single analysis. It has high resolving power and sensitivity, requires minimal volume (several nanoliters) and can analyze at high speed.
Electron ionizationElectron ionization (EI, formerly known as electron impact ionization and electron bombardment ionization) is an ionization method in which energetic electrons interact with solid or gas phase atoms or molecules to produce ions. EI was one of the first ionization techniques developed for mass spectrometry. However, this method is still a popular ionization technique. This technique is considered a hard (high fragmentation) ionization method, since it uses highly energetic electrons to produce ions.
Ion-mobility spectrometry–mass spectrometryIon mobility spectrometry–mass spectrometry (IMS-MS) is an analytical chemistry method that separates gas phase ions based on their interaction with a collision gas and their masses. In the first step, the ions are separated according to their mobility through a buffer gas on a millisecond timescale using an ion mobility spectrometer. The separated ions are then introduced into a mass analyzer in a second step where their mass-to-charge ratios can be determined on a microsecond timescale.
Désorption-ionisation par électronébulisationLa désorption-ionisation par électronébulisation (en, DESI) est une méthode d’ionisation communément utilisée en spectrométrie de masse. Cette méthode permet l’ionisation d’une grande variété de composés, incluant les peptides et les protéines présents dans les métaux, les polymères et la surface des minéraux. La DESI a même permis l’imagerie de tissus intacts de cerveau de rat sous des conditions ambiantes. Tout d’abord, la DESI est une méthode instrumentale regroupant les aspects de l’ESI (Electrospray Ionization) et de la famille des méthodes DI (Desorption Ionization).
Ion sourceAn ion source is a device that creates atomic and molecular ions. Ion sources are used to form ions for mass spectrometers, optical emission spectrometers, particle accelerators, ion implanters and ion engines. Electron ionization Electron ionization is widely used in mass spectrometry, particularly for organic molecules. The gas phase reaction producing electron ionization is M{} + e^- -> M^{+\bullet}{} + 2e^- where M is the atom or molecule being ionized, e^- is the electron, and M^{+\bullet} is the resulting ion.