Intensifying the response of distributed optical fibre sensors using 2D and 3D image restoration
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Laser Doppler Imaging (LDI) is a non-invasive optical technique used for assessing the blood flow in biological tissue. This technique allows visualizing 2D distribution of blood flow over an extended area of tissue, e.g. human skin. We have developed a ne ...
A generalization of the additive Gaussian two-way channel to M users is considered. Such channels contain implicit feedback in the sense that the channel output signals observed by the different encoders are correlated. While the benefits of feedback are s ...
Ieee Service Center, 445 Hoes Lane, Po Box 1331, Piscataway, Nj 08855-1331 Usa2008
This paper presents a safe, electrically powered MR-compatible actuator with a large range of output impedance, which can be used at the entry of the scanner bore. This actuator is composed of an ultrasonic motor (USM) and a torque-controlled electrorheolo ...
Ieee Service Center, 445 Hoes Lane, Po Box 1331, Piscataway, Nj 08855-1331 Usa2008
Autofluorescence bronchoscopy (AFB) has been shown to be a highly sensitive tool for the detection of early endobronchial cancers. When excited with blue-violet light, early neoplasia in the bronchi tend to show a decrease of autofluorescence in the green ...
In digital holographic microscopy, shot noise is an intrinsic part of the recording process with the digital camera. We present a study based on simulations and real measurements describing the shot-noise influence in the quality of the reconstructed phase ...
We describe the design and performance of a new full-field high-speed laser Doppler imaging system developed for mapping and monitoring of blood flow in biological tissue. The total imaging time for 256x256 pixels region of interest is 1.2 seconds. An inte ...
This paper describes the design and the performance of a new high-speed laser Doppler imaging system for monitoring blood flow over an area of tissue. The new imager delivers high-resolution flow images (256 x 256 pixels) every 2 to 10 seconds, depending o ...
The X-mode radial correlation reflectometry diagnostic on JET has long suffered from strong signal attenuation in the original transmission lines. To reach higher performances, new low-attenuation corrugated circular waveguides and a new cluster of six ant ...
The X-mode radial correlation reflectometry diagnostic on JET has long suffered from strong signal attenuation in the original transmission lines. To reach higher performances, new low-attenuation corrugated circular waveguides and a new cluster of six ant ...
The intent of this paper is to show how the accuracy of 3D position tracking can be improved by considering rover locomotion in rough terrain as a holistic problem. An appropriate locomotion concept endowed with a controller min- imizing slip improves the ...