A Capacitively-Coupled Chopper Instrumentation Amplifier for Implantable Bridge Sensor Systems
Graph Chatbot
Chattez avec Graph Search
Posez n’importe quelle question sur les cours, conférences, exercices, recherches, actualités, etc. de l’EPFL ou essayez les exemples de questions ci-dessous.
AVERTISSEMENT : Le chatbot Graph n'est pas programmé pour fournir des réponses explicites ou catégoriques à vos questions. Il transforme plutôt vos questions en demandes API qui sont distribuées aux différents services informatiques officiellement administrés par l'EPFL. Son but est uniquement de collecter et de recommander des références pertinentes à des contenus que vous pouvez explorer pour vous aider à répondre à vos questions.
Minimally invasive monitoring of the electrical activity of specific cortical areas using implantable microsystems offers the promise of diagnosing neurological diseases, as well as detecting and identifying neural activity patterns which are specific to a ...
This document concerns the deviation of the output of MilliNewton and CentoNewton force sensors from ideal ratiometric behaviour. These sensors nominally operate from a single +5 V supply voltage and, as they have no voltage regulator, their output respons ...
In this research we propose a novel inchworm robot, which is composed of an Electromagnetic Oscillatory Actuator (BOA) and claws. The EOA consists of a yoke, a magnet, and a coil. The overall robot size is 12.2 mm x 11 mm x 9 mm (length x height x width). ...
Science Press2015
A low power SAR logic-based resistive sensor readout circuit is proposed. A high sensitivity thermistor is used for local temperature measurements. The need for a low-noise front-end voltage amplifier is avoided by employing time-domain operation. In each ...
Institute of Electrical and Electronics Engineers2014
An impulse radio ultra wideband (IR-UWB) transmitter (Tx) using finite impulse response synthesis of the raised-cosine pulse is presented. Symmetric pulse combining technique is proposed to reduce the number of power amplifier elements by half. A novel all ...
This paper presents a neural recording amplifier array suitable for large-scale integration with multielectrode arrays in very low-power microelectronic cortical implants. The proposed amplifier is one of the most energy-efficient structures reported to da ...
An innovative readout channel, based on analog amplitude modulation (AM) of the signals recorded by each electrode, is developed for high-density CMOS-based MEAs. This new readout method enables the design of a low-noise amplification stage while still rea ...
2010
, , , ,
An Analog to Digital Converter (ADC) using the low duty-cycle nature of pulse-based Ultra Wide-Band (UWB) communications to reduce its power consumption is proposed. Implemented in CMOS 180 nm technology, it can capture a 5 ns window at 4 GS/s each 100 ns, ...
2014
, ,
A 16-channel neural action potential recording IC suitable for large-scale integration with multi-electrode arrays (MEAs) is presented. A closed-loop gain of 60 dB in the action potential band is achieved by cascading differential gain-stages utilizing a n ...
We present a fully integrated CMOS receiver for micro-magnetic resonance imaging together with a custom-made micro-gradient system. The receiver is designed for an operating frequency of 300 MHz. The chip consists of an on-chip detection coil and tuning ca ...