Microelectrode arrayMicroelectrode arrays (MEAs) (also referred to as multielectrode arrays) are devices that contain multiple (tens to thousands) microelectrodes through which neural signals are obtained or delivered, essentially serving as neural interfaces that connect neurons to electronic circuitry. There are two general classes of MEAs: implantable MEAs, used in vivo, and non-implantable MEAs, used in vitro. Neurons and muscle cells create ion currents through their membranes when excited, causing a change in voltage between the inside and the outside of the cell.
Interface neuronale directethumb|250px|Schéma d'une interface neuronale directe. Une interface neuronale directe - abrégée IND ou BCI ou encore ICM (interface cerveau-machine, ou encore interface cerveau-ordinateur) est une interface de communication directe entre un cerveau et un dispositif externe (un ordinateur, un système électronique...). Ces systèmes peuvent être conçus dans le but d'étudier le cerveau, d'assister, améliorer ou réparer des fonctions humaines de cognition ou d'action défaillantes. L'IND peut être unidirectionnelle ou bidirectionnelle.
ÉlectroencéphalographieL'électroencéphalographie (EEG) est une méthode d'exploration cérébrale qui mesure l'activité électrique du cerveau par des électrodes placées sur le cuir chevelu souvent représentée sous la forme d'un tracé appelé électroencéphalogramme. Comparable à l'électrocardiogramme qui permet d'étudier le fonctionnement du cœur, l'EEG est un examen indolore et non invasif qui renseigne sur l'activité neurophysiologique du cerveau au cours du temps et en particulier du cortex cérébral soit dans un but diagnostique en neurologie, soit dans la recherche en neurosciences cognitives.
ÉlectrophysiologieL'électrophysiologie (du grec el, elektron, el, physis, nature, et -el, -logia, étude) est l'étude des phénomènes électriques et électrochimiques qui se produisent dans les cellules ou les tissus des organismes vivants et, en particulier, dans les neurones et les fibres musculaires et chez les plantes sensitives (étudiées depuis le début du siècle de ce point de vue, dont par Jagadish Chandra Bose). Elle implique la mesure de différences de tensions ou de courants électriques à différentes échelles biologiques, du canal ionique isolé, jusqu'à des organes entiers, comme le cœur.
Cultured neuronal networkA cultured neuronal network is a cell culture of neurons that is used as a model to study the central nervous system, especially the brain. Often, cultured neuronal networks are connected to an input/output device such as a multi-electrode array (MEA), thus allowing two-way communication between the researcher and the network. This model has proved to be an invaluable tool to scientists studying the underlying principles behind neuronal learning, memory, plasticity, connectivity, and information processing.
Single-unit recordingIn neuroscience, single-unit recordings (also, single-neuron recordings) provide a method of measuring the electro-physiological responses of a single neuron using a microelectrode system. When a neuron generates an action potential, the signal propagates down the neuron as a current which flows in and out of the cell through excitable membrane regions in the soma and axon. A microelectrode is inserted into the brain, where it can record the rate of change in voltage with respect to time.
Modèles du neurone biologiquevignette|390x390px|Fig. 1. Dendrites, soma et axone myélinisé, avec un flux de signal des entrées aux dendrites aux sorties aux bornes des axones. Le signal est une courte impulsion électrique appelée potentiel d'action ou impulsion. vignette|Figure 2. Évolution du potentiel postsynaptique lors d'une impulsion. L'amplitude et la forme exacte de la tension peut varier selon la technique expérimentale utilisée pour acquérir le signal.
Liquid metal electrodeA liquid metal electrode is an electrode that uses a liquid metal, such as mercury, Galinstan, and NaK. They can be used in electrocapillarity, voltammetry, and impedance measurements. The dropping mercury electrode (DME) is a working electrode made of mercury and used in polarography. Experiments run with mercury electrodes are referred to as forms of polarography even if the experiments are identical or very similar to a corresponding voltammetry experiment which uses solid working electrodes.
Électrode de référenceUne électrode de référence est une électrode qui maintient un potentiel pratiquement invariant dans les conditions prévalant dans une mesure électrochimique. Elle permet l'observation, la mesure ou le contrôle du potentiel de l'indicateur (ou de l'essai) ou de l'électrode de travail.On l'utilise en électrochimie pour étudier les propriétés d'oxydoréduction et en chimie analytique pour mesurer les concentrations d'espèces dissoutes dans une solution. Le potentiel de l'électrode de référence ne doit en aucun cas varier pendant la mesure.
Électroencéphalographie intracrânienneL'électroencéphalographie intracrânienne dite aussi intra-cérébrale, sous-durale, stéréotaxique (SEEG) est une méthode d'enregistrement de l'activité du cerveau au moyen d'électrodes implantées en profondeur sous la boîte crânienne utilisée notamment en neurologie, dans le diagnostic pré-chirurgical de l'épilepsie.