Heat fluxIn physics and engineering, heat flux or thermal flux, sometimes also referred to as heat flux density, heat-flow density or heat flow rate intensity, is a flow of energy per unit area per unit time. Its SI units are watts per square metre (W/m2). It has both a direction and a magnitude, and so it is a vector quantity. To define the heat flux at a certain point in space, one takes the limiting case where the size of the surface becomes infinitesimally small.
Infrared windowThe infrared atmospheric window refers to a region of the Infrared spectrum where there is relatively little absorption of terrestrial thermal radiation by atmospheric gases. The window plays an important role in the atmospheric greenhouse effect by maintaining the balance between incoming solar radiation and outgoing IR to space. In the Earth's atmosphere this window is roughly the region between 8 and 14 μm although it can be narrowed or closed at times and places of high humidity because of the strong absorption in the water vapor continuum or because of blocking by clouds.
Couche limitevignette|redresse=2|Couches limites laminaires et turbulentes d'un écoulement sur une plaque plane (avec profil des vitesses moyennes). La couche limite est la zone d'interface entre un corps et le fluide environnant lors d'un mouvement relatif entre les deux. Elle est la conséquence de la viscosité du fluide et est un élément important en mécanique des fluides (aérodynamique, hydrodynamique), en météorologie, en océanographie vignette|Profil de vitesses dans une couche limite.
Phénomène de transfertUn phénomène de transfert (ou phénomène de transport) est un phénomène irréversible durant lequel une grandeur physique est transportée par le biais de molécules. C'est un phénomène transversal présent dans tous les domaines de la science et en ingénierie. Tous les phénomènes de transport ont pour origine l'inhomogénéité d'une grandeur intensive. C'est la tendance spontanée des systèmes physiques et chimiques à rendre uniformes ces grandeurs qui provoquent le transport.
Bloc fonctionnelvignette|Schéma fonctionnel comportant un générateur de tension idéal et une résistance. La modélisation par blocs fonctionnels simplifie la description du comportement d'un système physique distribué en le réduisant à un graphe (ou « topologie ») constitué d’éléments séparés, les blocs fonctionnels. Elle intervient dans les domaines les plus variés, depuis le réseau de distribution à la linguistique en passant par les circuits (thermiques, électriques ou électroniques, pneumatiques, hydrauliques), les robots, l'acoustique, etc.
Critical heat fluxIn the study of heat transfer, critical heat flux (CHF) is the heat flux at which boiling ceases to be an effective form of transferring heat from a solid surface to a liquid. Boiling systems are those in which liquid coolant absorbs energy from a heated solid surface and undergoes a change in phase. In flow boiling systems, the saturated fluid progresses through a series of flow regimes as vapor quality is increased. In systems that utilize boiling, the heat transfer rate is significantly higher than if the fluid were a single phase (i.
Sadi Carnot (physicien)Nicolas Léonard Sadi Carnot est un physicien et ingénieur français né le à Paris et mort le à Ivry-sur-Seine. Durant sa courte carrière (il meurt du choléra à l’âge de ), Sadi Carnot ne publia qu’un seul livre (comme Copernic) : Réflexions sur la puissance motrice du feu et sur les machines propres à développer cette puissance, en 1824, dans lequel il exprima, à l’âge de , ce qui s’avéra être le travail de sa vie et un livre important dans l’histoire de la physique.
Effet de serreL'effet de serre est un processus naturel résultant de l'influence de l'atmosphère sur les différents flux thermiques contribuant aux températures au sol d'un objet céleste. La prise en compte de ce processus est nécessaire pour comprendre les températures observées à la surface des planètes ou satellites recouverts d'une atmosphère épaisse comme la Terre, Vénus et Titan, et le processus doit se produire aussi pour certaines exoplanètes. Le terme fait référence à l'effet analogue qu'une serre a sur la température des plantations qu'elle abrite.
Lois de Fickvignette|250px|La diffusion moléculaire d'un point de vue microscopique et macroscopique. Les molécules solubles sur le côté gauche de la barrière (ligne violette) diffusent pour remplir le volume complet. En haut : une seule molécule se déplace aléatoirement. Au milieu : Le soluté remplit le volume disponible par marche aléatoire. En bas : au niveau macroscopique, le côté aléatoire devient indétectable. Le soluté se déplace des zones où les concentrations sont élevées vers les zones à concentrations plus faibles.
Loi du déplacement de WienEn physique, la loi du déplacement de Wien, ainsi nommée d'après son découvreur Wilhelm Wien, est une loi selon laquelle la longueur d'onde à laquelle un corps noir émet le plus de flux lumineux énergétique est inversement proportionnelle à sa température. La loi de Wien se déduit de la loi de Planck du rayonnement du corps noir. La loi de Planck décrit la distribution de l'énergie W(λ) rayonnée en fonction de la température T du corps noir. Selon la loi de Planck, à une température T donnée, l'énergie W(λ) passe par un maximum Wmax pour une longueur d'onde λmax.